<rt id="yo26q"><delect id="yo26q"></delect></rt>
  • <rt id="yo26q"></rt>
  • <strike id="yo26q"></strike>
    <li id="yo26q"><source id="yo26q"></source></li>
    <bdo id="yo26q"></bdo>
    <bdo id="yo26q"></bdo>
  • <strike id="yo26q"><acronym id="yo26q"></acronym></strike>
    <center id="yo26q"></center>
    全國銷售熱線0755-23312011

    檢測認證行業資訊

    法規速遞/ 沙特阿拉伯強制EMC電磁兼容技術法規

    沙特標準、計量和質量組織(SASO)于2023年11月17日發布的《電磁兼容性技術法規》于2024年5月17日正式執行。

    法規旨在規定設備電磁兼容性的標準要求并確定供應商應遵守的合格評定程序,確保產品符合保護用戶環境、健康和安全的基本要求,并促進市場監督程序。根據合格評定程序,沙特進口商在Saber平臺申請清關證書PCOC和SCOC時,應提供供應商合格聲明和EMC測試報告以證明產品滿足技術法規。

    該技術法規適用于附錄Annex I所列的標準定義相關術語的設備(請參考下圖法規原文):

    Annex I    

    Sr.    Title of Standard in English    Standard No.    

    1    Rotating electrical machines-Part 1: Rating and performance    SASO IEC 60034-1    

    2    Safety of machinery – Electrical equipment of machines - Part 31: Particular safety and EMC requirements for sewing machines, units and systems    SASO IEC 60204-31    

    3    Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirement    SASO GSO IEC 60255-26    

    4    Switches for household and similar fixed electrical installations - Part 2-1: Particular requirements – Electronic switches    SASO IEC 60669-2-1    

    5    Automatic electrical controls- Part 1: General requirements    SASO GSO IEC 60730-1    

    6    Automatic electrical controls- Part 2-5: Particular requirements for automatic electrical burner control systems    SASO GSO IEC 60730-2-5    

    7    Automatic electrical controls- Part 2-6: Particular requirements for automatic electrical pressure sensing controls including mechanical requirements    SASO GSO IEC 60730-2-6    

    8    Automatic electrical controls- Part 2-7: Particular requirements for timers and time switches    SASO GSO IEC 60730-2-7    

    9    Automatic electrical controls- Part 2-8: Particular requirements for electrically operated water valves, including mechanical requirements    SASO GSO IEC 60730-2-8    

    10    Automatic electrical controls- Part 2-9: Particular requirements for temperature sensing control    SASO GSO IEC 60730-2-9    

    11    Automatic electrical controls- Part 2-14: Particular requirements for electric actuators    SASO GSO IEC 60730-2-14    

    12    Automatic electrical controls- Part 2-15: Particular requirements for automatic electrical air flow, water flow and water level sensing controls    SASO GSO IEC 60730-2-15    

    13    Telecontrol equipment and systems - Part 2: Operating conditions - Section 1: Power supply and electromagnetic compatibility    SASO GSO IEC 60870-2-1    

    14    Low-voltage switchgear and controlgear - Part 1: General rules    SASO GSO IEC 60947-1    

    15    Low-voltage switchgear and controlgear - Part 2: Circuit- breakers    SASO GSO IEC 60947-2    

    16    low-voltage switchgear and controlgear - Part 3: Switches, disconnectors, switchdisconnectors and fusecombination units    SASO GSO IEC 60947-3    

    17    Low-voltage switchgear and controlgear - Part 4-1: Contactors and motor-starters - Electromechanical contactors and motor starters    SASO IEC 60947-4-1    

    18    Low-voltage switchgear and controlgear - Part 4-2: Contactors and motor-starters – AC semiconductor motor controllers and starters    SASO IEC 60947-4-2    

    19    low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters – AC semiconductor controllers and contactors for non-motor loads    SASO IEC 60947-4-3    

    20    Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements – Electromechanical control circuit devices    SASO IEC 60947-5-1    

    21    low-voltage switchgear and controlgear - Part 5-2: Control circuit devices and switching elements - Proximity switches    SASO IEC 60947-5-2    

    22    Low-voltage switchgear and controlgear - Part 5-3: Control circuit devices and switching elements - Requirements for proximity devices with defined behaviour under fault conditions (PDDB)    SASO IEC 60947-5-3    

    23    Low-voltage switchgear and controlgear - Part 5-6: Control circuit devices and switching elements - DC interface for proximity sensors and switching amplifiers (NAMUR)    SASO IEC 60947-5-6    

    24    Low-voltage switchgear and controlgear - Part 5-7: Control circuit devices and switching elements - Requirements for proximity devices with analogue output    SASO IEC 60947-5-7    

    25    Low-voltage switchgear and controlgear - Part 5-9: Control circuit devices and switching elements - Flow rate switches    SASO IEC 60947-5-9    

    26    Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment – Transfer switching equipment    SASO IEC 60947-6-1    

    27    Low-voltage switchgear and controlgear - Part 6-2: Multiple function equipment-Control and protective switching devices (or equipment) (CPS)    SASO IEC 60947-6-2    

    28    Low-voltage switchgear and controlgear - Part 8: Control units for built-in thermal protection (PTC) for rotating electrical machines    SASO IEC 60947-8    

    29    Low-voltage switchgear and controlgear - Part 9-1: Active arc- fault mitigation systems – Arc quenching devices    IEC 60947-9-1    

    30    Arc welding equipment - Part 10: Electromagnetic compatibility (EMC) requirements    SASO IEC 60974-10    

    31    Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current < 16 A per phase)    SASO GSO IEC 61000-3-2    

    32    Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection    SASO IEC 61000-3-3    

    33    Electromagnetic compatibility (EMC) - Part 3-11: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems - Equipment with rated current <= 75 A and subject to conditional connection    SASO IEC 61000-3-11    

    34    Electromagnetic compatibility (EMC) - Part 3-12: Limits - Limits for harmonic currents produced by equipment connected to public low-voltage systems with input current > 16 A and <=75 A per phase    SASO IEC 61000-3-12    

    35    Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light- industrial environments    SASO IEC 61000-6-1    

    36    Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments    SASO IEC 61000-6-2    

    37    Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments    IEC 61000-6-3    

    38    Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments    SASO IEC 61000-6-4    

    39    Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for equipment used in power station and substation environment    SASO IEC 61000-6-5    

    40    Residual current operated circuit- breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part 1: General rules    SASO IEC 61008-1    

    41    Residual current operated circuit- breakers with integral overcurrent protection for household and similar uses (RCBOs) - Part 1: General rules    SASO IEC 61009-1    

    42    Switches for appliances - Part 1: General requirements    SASO IEC 61058-1    

    43    Industrial-process measurement and control - Programmable controllers - Part 2: Equipment requirements and tests    IEC 61131-2    

    44    Low-voltage switch mode power supplies - Part 3: Electromagnetic compatibility (EMC)    SASO IEC 61204-3    

    45    Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 1: General requirements    SASO IEC 61326-1    

    46    Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-1: Particular requirements - Test configurations, operational conditions and performance criteria for sensitive test and measurement equipment for EMC unprotected applications    SASO IEC 61326-2-1    

    47    Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-2: Particular requirements - Test configurations, operational conditions and performance criteria for portable test, measuring and monitoring equipment used in low-voltage distribution systems    SASO IEC 61326-2-2    

    48    Electrical equipment for measurement, control and laboratory use- use - EMC requirements - Part 2-3: Particular requirements - Test configuration, operational conditions and performance criteria for transducers with integrated or remote signal conditioning    SASO IEC 61326-2-3    

    49    Low-voltage switchgear and controlgear assemblies - Part 1: General rules    SASO IEC 61439-1    

    50    Low-voltage switchgear and controlgear assemblies - Part 2: Power switchgear and controlgear assemblies    SASO IEC 61439-2    

    51    Low-voltage switchgear and controlgear assemblies - Part 3: Distribution boards intended to be operated by ordinary persons (DBO)    SASO IEC 61439-3    

    52    Low-voltage switchgear and controlgear assemblies - Part 4: Particular requirements for assemblies for construction sites (ACS)    IEC 61439-4    

    53    Low-voltage switchgear and controlgear assemblies - Part 5: Assemblies for power distribution in public networks    SASO IEC 61439-5    

    54    Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways)    SASO GSO IEC 61439-6    

    55    Residual current-operated protective devices (RCDs) for household and similar use- Electromagnetic compatibility    SASO IEC 61543    

    56    Equipment for general lighting purposes - EMC immunity requirements    SASO IEC 61547    

    57    Electrical safety in low voltage distribution systems up to 1 000 Va.c. and 1 500 V d.c.- Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD)    SASO IEC 61557-12    

    58    Electrical accessories - Residual current monitors for household and similar uses (RCMs)    SASO IEC 62020    

    59    Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 1: General rules    SASO IEC 62026-1    

    60    Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 2: Actuator sensor interface (AS-i)    SASO IEC 62026-2    

    61    Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 3: DeviceNet    SASO IEC 62026-3    

    62    Low-voltage switchgear and controlgear-Controller-device interfaces (CDIs) - Part 7: CompoNe    SASO IEC 62026-7    

    63    Uninterruptible power systems (UPS) - Part 2: Electromagnetic compatibility (EMC) requirements    SASO IEC 62040-2    

    64    Electricity metering equipment (a.c.) - General requirements, tests and test conditions - Part 21: Tariff and load control equipment    SASO IEC 62052-21    

    65    Electricity metering equipment (a.c.)- Particular requirements- Part 11: Electromechanical meters for active energy (classes 0,5, 1and 2)    SASO IEC 62053-11    

    66    Electricity metering equipment- Particular requirements - Part 21: Static meters for AC active energy (classes 0,5, 1 and 2)    IEC 62053-21    

    67    Electricity metering equipment- Particular requirements - Part 22: Static meters for AC active energy (classes 0,15, 0,25 and 0,55)    SASO IEC 62053-22    

    68    Electricity metering equipment - Particular requirements - Part 23: Static meters for reactive energy (classes 2 and 3)    SASO IEC 62053-23    

    69    Electricity metering (a.c.)-Tariff and load control - Part 11: Particular requirements for electronic ripple control receivers    SASO IEC 62054-11    

    70    Electricity metering (a.c.) - Tariff and load control - Part 21: Particular requirements for time switches    SASO IEC 62054-21    

    71    Resistance welding equipment - Part 2: Electromagnetic compatibility (EMC) requirements    SASO IEC 62135-2    

    72    Static transfer systems (STS) - Part 2: Electromagnetic compatibility (EMC) requirements    SASO IEC 62310-2    

    73    Type F and type B residual current operated circuit-breakers with and without integral overcurrent protection for household and similar uses    SASO IEC 62423    

    74    Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI)    SASO IEC 62586-1    

    75    Power quality measurement in power supply systems - Part 2: Functional tests and uncertainty requirements    SASO IEC 62586-2    

    76    General requirements for arc fault detection and protection devices (AFDDs)    SASO IEC 62606    

    77    Requirements for automatic reclosing devices (ARDS) for circuit-breakers, RCBOs and RCCBs for household and similar uses    SASO GSO IEC 63024    

    78    Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement    SASO CISPR 11    

    79    Vehicles, boats and internal combustion engines - Radio disturbance characteristics- Limits and methods of measurement for the protection of off-board receivers    SASO CISPR 12    

    80    Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission    SASO CISPR 14-1    

    81    Electromagnetic compatibility- Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard    SASO CISPR 14-2    

    82    Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment    SASO CISPR 15    

    83    Electromagnetic compatibility of multimedia equipment -Emission requirements    SASO CISPR 32    

    84    Electromechanical elementary relays - Part 1: General and safety requirements    SASO IEC 61810-1    

    下列設備屬于法規豁免范圍:

    無線電設備和電信終端設備

    航空航天產品及其零部件

    業余愛好者使用的通訊設備

    醫療設備

    具有以下物理特性的設備

    不能產生或促成電磁發射的設備,其電磁發射超過允許無線電和電信設備及其他設備按預期工作的水平。

    正常使用時不受電磁干擾影響的設備

    為專家設計并直接用于研究和開發為目的的電子面板


    深圳訊科標準技術為第三方檢測機構,專業提供:3C認證,KC認證,CE認證, CCC認證, UV老化測試, 高低溫測試, 聲學測試, 老化壽命測試, 有害物質檢測, 軟件測試測評, 防水防塵測試, 第三方檢測中心, 危廢鑒定, 第三方測試報告, ROHS環保認證, FCC認證, PSE認證, BQB認證, CB認證, SRRC型號核準, 防爆認證, 可靠性測試, 氙燈老化測試, ISTA包裝運輸測試, 氣體腐蝕測試, 振動沖擊測試, 冷熱沖擊測試, WF2腐蝕等級測試, MTBF認證測試, 失效分析, 材料檢測中心, 建筑材料檢測, 連接器測試, 噪音測試, 環保檢測, 環境檢測, 水質檢測, 材質鑒定, MSDS認證報告, 運輸鑒定報告, 質檢報告, 烤箱檢測, 亞馬遜UL檢測報告, 防火測試, 玩具檢測, 電子產品質量檢測中心, 食品接觸材料檢測, 材料成分分析, 生物降解檢測, reach測試,歡迎您的來電。


    版權所有Copyright(C)2013-2015深圳市訊科標準技術服務有限公司粵ICP備16026918號-2


    網站地圖 XML

    咨詢熱線:0755-23312011

    主站蜘蛛池模板: 沂水县| 光泽县| 扶余县| 疏附县| 黄梅县| 达拉特旗| 固镇县| 东阳市| 黄冈市| 神农架林区| 大余县| 新疆| 鄄城县| 成都市| 霍林郭勒市| 山东省| 南木林县| 买车| 吉林市| 永定县| 香格里拉县| 庆安县| 闸北区| 宁津县| 绥芬河市| 册亨县| 德格县| 宜城市| 肇州县| 株洲县| 安吉县| 永仁县| 石狮市| 米林县| 文成县| 上林县| 凤城市| 阿图什市| 通化市| 新疆| 抚顺市|